{"product_id":"zurn-wilkins-112-975xl2u-rp-backflow-preventer-1-12-inches","title":"Wilkins 112-975XL2U | RP Backflow Preventer, 1 1\/2 Inches","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\nThe Wilkins 112-975XL2U is a reduced pressure principle backflow prevention assembly designed to protect potable water supplies from contamination due to backsiphonage and backpressure where a health hazard exists.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003eSize:\u003c\/strong\u003e\n    1 1\/2 Inches\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e\n    175 PSI\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e\n    180°F\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e\n    ASSE 1013, cUPC, CSA B64.4\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eEnd Connections:\u003c\/strong\u003e\n    Threaded ANSI B1.20.1\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e1-975XL2U:\u003c\/strong\u003e\n    1 Inch model size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e2-975XL2U:\u003c\/strong\u003e\n    2 Inches model size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e34-975XL2U:\u003c\/strong\u003e\n    3\/4 Inch model size\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n  \u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n  \u003cli\u003eFasteners: 300 Series Stainless Steel\u003c\/li\u003e\n  \u003cli\u003eElastomers: Silicone and Buna Nitrile\u003c\/li\u003e\n  \u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n  \u003cli\u003eSprings: 300 Series Stainless Steel\u003c\/li\u003e\n  \u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 Inches and a maximum of 30 Inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, the installation shall be supplied with an air gap adapter.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets NSF\/ANSI\/CAN 61 and 372; UL Classified; C-UL Classified\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides robust protection against both backsiphonage and backpressure of contaminated water into potable water supplies where a potential health hazard exists.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 61 and 372 standards with less than 0.25% weighted average lead content, ideal for use where lead-free valves are required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Materials:\u003c\/strong\u003e Features low lead cast bronze body, 300 series stainless steel fasteners and springs, and silicone elastomers for long-lasting performance and corrosion resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e The Zurn 112-975XL2U first and second checks are accessible for maintenance without removing the relief valve or the entire device from the line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the required installation height for the Wilkins 112-975XL2U?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 Inches and a maximum of 30 Inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is an air gap fitting required for this backflow preventer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, if the Zurn 112-975XL2U is installed indoors, the installation shall be supplied with an air gap adapter to prevent submersion of the unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What type of connection does this assembly have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly comes standard with full port union ball valves and threaded end connections conforming to ANSI B1.20.1.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n  \u003cp\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003eNOTICE:\u003c\/strong\u003e\n      Do not use with water that is unsafe or of unknown quality without adequate\n      disinfection either before or after the system.\n    \u003c\/span\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n  \u003ci\u003e\n    \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n    \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\n      Contact us\n    \u003c\/a\u003e\n  \u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914915090495,"sku":"112-975XL2U","price":2019.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/114_2-975XL2_AL_e2c3bccb-ab8a-4acb-bb5b-26ef62523bd8.png?v=1770569039","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-112-975xl2u-rp-backflow-preventer-1-12-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}