{"product_id":"zurn-wilkins-112-975xl2sag-1-12-rpz-backflow-preventer-with-strainer-air-gap","title":"Wilkins 112-975XL2SAG | 1 1\/2\" RPZ Backflow Preventer with Strainer \u0026 Air Gap","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\nThe Wilkins 112-975XL2SAG is a reduced pressure principle backflow prevention assembly designed to protect potable water systems from contamination where potential health hazards exist.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-975XL2SAG:\u003c\/strong\u003e 3\/4 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2SAG:\u003c\/strong\u003e 1 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-975XL2SAG:\u003c\/strong\u003e 1 1\/4 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-975XL2SAG:\u003c\/strong\u003e 2 Inch model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone and Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 Inches and a maximum of 30 Inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. The included air gap fitting is required for indoor installations.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1013; cUPC; CSA B64.4; AWWA C511; UL\/C-UL Classified; NSF\/ANSI\/CAN 61 \u0026amp; 372\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides comprehensive protection against both backsiphonage and backpressure contamination of potable water systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 372 requirements with less than 0.25% weighted average lead content for safe drinking water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Configuration:\u003c\/strong\u003e Compatible with optional excessive discharge sensor for flood detection and includes bronze Y-type strainer with air gap accessory for enhanced system protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the proper installation height for the Zurn 112-975XL2SAG?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 Inches and a maximum of 30 Inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the air gap fitting required for all installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The included air gap fitting is required for indoor installations to ensure proper drainage and prevent submersion of the unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What type of valve handles come standard with the Wilkins 112-975XL2SAG?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit comes standard with full port QT ball valves featuring stainless steel handles for durability and reliable operation.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914915057727,"sku":"112-975XL2SAG","price":2463.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/114_2-975XL2_AL_da7489ce-ee35-42a5-8f6e-2d481f680689.png?v=1770569034","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-112-975xl2sag-1-12-rpz-backflow-preventer-with-strainer-air-gap","provider":"BottleFillingStations.com","version":"1.0","type":"link"}