{"product_id":"zurn-wilkins-112-975xl2ft-1-12-backflow-preventer-rp-assembly","title":"Wilkins 112-975XL2FT | 1 1\/2\" Backflow Preventer, RP Assembly","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\nThe Wilkins 112-975XL2FT is a Reduced Pressure Principle Backflow Prevention Assembly designed to protect potable water supplies from contamination where potential health hazards exist.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2FT:\u003c\/strong\u003e 1 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-975XL2FT:\u003c\/strong\u003e 2 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-975XL2FT:\u003c\/strong\u003e 3\/4 Inch model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone\/Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall valve handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 Inches (305mm) and a maximum of 30 Inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. If installed indoors, the installation shall be supplied with an air gap adapter.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets the requirements of NSF\/ANSI\/CAN 61 and 372; UL Classified (less shut-off valves or with OS\u0026amp;Y valves); C-UL Classified\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Certified to NSF\/ANSI\/CAN 61 and 372 with less than 0.25% weighted average lead content, ideal for potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Protection Design:\u003c\/strong\u003e Protects against both backsiphonage and backpressure of contaminated water into potable water supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Ball Valves:\u003c\/strong\u003e Equipped with full port QT ball valves and integral male 45° flare SAE test fittings for convenient testing and shut-off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the required installation height for the Zurn 112-975XL2FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 Inches and a maximum of 30 Inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins 112-975XL2FT be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, it can be installed outdoors with a protective enclosure. However, the installation must ensure that no part of the unit can be submerged.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is an air gap fitting required for indoor installations of the Zurn 112-975XL2FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, if installed indoors, the installation shall be supplied with an air gap adapter (Model AG) as specified in the installation requirements.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914915024959,"sku":"112-975XL2FT","price":1993.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/114_2-975XL2_AL_29a9e35d-3e3c-4a4f-98e2-20246e46f7b5.png?v=1770569029","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-112-975xl2ft-1-12-backflow-preventer-rp-assembly","provider":"BottleFillingStations.com","version":"1.0","type":"link"}