{"product_id":"zurn-wilkins-112-950xl3ft-1-12-reduced-pressure-backflow-assembly","title":"Wilkins 112-950XL3FT | 1 1\/2\" Reduced Pressure Backflow Assembly","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 112-950XL3FT is a lead-free reduced pressure principle backflow prevention assembly designed to protect potable water supplies from contamination.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded FNPT ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-950XL3FT:\u003c\/strong\u003e 2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA Approved)\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12\" (305mm) and a maximum of 30\" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE 1013; cUPC; CSA B64.4; UL Classified; AWWA C511; Meets NSF\/ANSI\/CAN 61 \u0026amp; 372\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 372 with less than 0.25% weighted average lead content for safe potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Protection:\u003c\/strong\u003e Protects against both backsiphonage and backpressure of contaminated water into the potable water supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Ball Valves:\u003c\/strong\u003e Standard full port QT ball valves with integral male 45° flare SAE test fittings provide optimal flow and convenient testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum working pressure for the Zurn 112-950XL3FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The minimum working water pressure is 25 PSI, with a maximum of 175 PSI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of installation clearance is required for the Zurn Wilkins 112-950XL3FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted 12\" to 30\" above adequate drains with sufficient side clearance for testing and maintenance, ensuring no part can be submerged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins 112-950XL3FT be used where lead-free valves are required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 112-950XL3FT is certified to NSF\/ANSI\/CAN 372 and is ideal for use where lead-free valves are required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" rel=\"noopener\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914914959423,"sku":"112-950XL3FT","price":1279.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/1-975XL3_F_0888af2e-6b59-4c20-8f80-e1f5f6f33dae.png?v=1770569024","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-112-950xl3ft-1-12-reduced-pressure-backflow-assembly","provider":"BottleFillingStations.com","version":"1.0","type":"link"}