{"product_id":"zurn-wilkins-112-600xlc-1-12-water-pressure-reducing-valve-with-bypass","title":"Wilkins 112-600XLC | 1 1\/2\" Water Pressure Reducing Valve with Bypass","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\nThe Wilkins 112-600XLC is a 1 1\/2\" water pressure reducing valve with integral by-pass check valve and strainer, designed for residential and commercial potable water systems requiring reliable pressure control and thermal expansion protection.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, IAPMO, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Copper Sweat Connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-600XLC:\u003c\/strong\u003e 1\/2 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-600XLC:\u003c\/strong\u003e 3\/4 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-600XLC:\u003c\/strong\u003e 1 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-600XLC:\u003c\/strong\u003e 1 1\/4 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-600XLC:\u003c\/strong\u003e 2 Inch version\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze (ASTM B 584)\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze\/Brass (ASTM B 584)\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel (300 Series)\u003c\/li\u003e\n\u003cli\u003eStem \u0026amp; plunger: Low Lead Cast Bronze\/Brass (ASTM B 584)\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA Approved), EPDM (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eCap gaskets: Natural Vulcanized Fibre, Acetal (Delrin™)\u003c\/li\u003e\n\u003cli\u003eStrainer screen: Stainless Steel (300 Series)\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel (300 Series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The Model 600XL may be installed in any position. If installed in a pit, vault or inside application, specify the \"SC\" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1003; IAPMO Listed; CSA Certified; City of Los Angeles Approved; NSF\/ANSI\/CAN 61\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral By-pass Check Valve:\u003c\/strong\u003e Prevents buildup of excessive system pressure caused by thermal expansion, protecting your plumbing system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Ensures smooth and responsive reaction to changes in system flow demand while providing protection from inlet pressure changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Strainer:\u003c\/strong\u003e Built-in strainer makes the Zurn 112-600XLC suitable for systems requiring frequent cleaning due to sediment and debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Installation:\u003c\/strong\u003e Can be installed in any position, with sealed cage option available for pit, vault, or indoor applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the factory preset pressure for the Zurn Wilkins 112-600XLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Wilkins 112-600XLC comes factory preset at 50 psi, with a standard adjustable pressure range of 25 psi to 75 psi.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the 112-600XLC be installed vertically or horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Model 600XL can be installed in any position. For pit, vault, or indoor installations, the \"SC\" sealed cage option should be specified.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: When should multiple pressure reducing valves be used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (for example, reducing 200 psi inlet to 50 psi outlet).\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914914893887,"sku":"112-600XLC","price":1294.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/600XLclr_ad37d4be-f1bd-43f2-8ac3-a2c963411695.png?v=1770569016","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-112-600xlc-1-12-water-pressure-reducing-valve-with-bypass","provider":"BottleFillingStations.com","version":"1.0","type":"link"}