{"product_id":"wilkins-zw5004ilg-pressure-tru-floor-control-valve-2-12-inches","title":"Wilkins ZW5004ILG | Pressure-Tru Floor Control Valve, 2-1\/2 Inches","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins ZW5004ILG is a Pressure-Tru pressure reducing floor control valve designed for automatic sprinkler and standpipe systems with field-adjustable regulation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inlet Pressure:\u003c\/strong\u003e 400 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e UL and C-UL Listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Grooved x Grooved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Cast bronze ASTM B806\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZW5004:\u003c\/strong\u003e Angle type valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZW5004IL:\u003c\/strong\u003e In-line globe type valve with FNPT connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZW5004G:\u003c\/strong\u003e Angle type with grooved inlet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZW5004CAP:\u003c\/strong\u003e Capped bonnet version without handwheel and supervisory switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZW5004ILCAP:\u003c\/strong\u003e In-line capped bonnet version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Cast bronze ASTM B806\u003c\/li\u003e\n\u003cli\u003eStem: Cast bronze ASTM B806\u003c\/li\u003e\n\u003cli\u003eFlange: Cast bronze ASTM B806\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile and EPDM\u003c\/li\u003e\n\u003cli\u003eSprings: Chrome silicon ASTM A401, powder coated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eThe Zurn ZW5004ILG is designed for installation in automatic sprinkler systems as a floor control valve, indicating valve, and check valve, as well as standpipe valve applications for CLASS I and CLASS III systems where pressure regulation under flow and no-flow conditions is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eUL Listed; C-UL Listed; ANSI B1.20.1; AWWA C606; ASTM B806; ASTM A401\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Adjustable Pressure Regulation:\u003c\/strong\u003e Can be factory set or field adjusted to meet specific application requirements for immediate on-site modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Supervisory Switch:\u003c\/strong\u003e Built-in tamper resistant supervisory switch rated 3 amps at 125VAC with rotatable housing for easy wiring installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Pressure Monitoring:\u003c\/strong\u003e Tapped and plugged inlet and outlet ports on both sides allow for convenient pressure gauge installation and system monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Function Design:\u003c\/strong\u003e Listed as floor control valve, indicating valve, and check valve providing versatile fire protection system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the ZW5004ILG and other ZW5004 variants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The ZW5004ILG features an in-line (globe type) body configuration with grooved end connections, while the standard ZW5004 has an angle body with FNPT connections. The CAP suffix variants eliminate the handwheel assembly and supervisory switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins ZW5004ILG be used for both indoor and outdoor installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Zurn ZW5004ILG is suitable for both indoor and outdoor use in automatic sprinkler and standpipe systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum outlet pressure setting for sprinkler system applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The minimum setting for sprinkler systems is 50 PSI as indicated in the residual pressure performance charts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42983795228735,"sku":"ZW5004ILG","price":1227.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/ZW5004_AR_91228717-7498-4a29-9d8e-dfe38d485f35.png?v=1772855024","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-zw5004ilg-pressure-tru-floor-control-valve-2-12-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}