{"product_id":"wilkins-ag-14-air-gap-adaptor-fitting-810-backflow-preventers","title":"Wilkins AG-14 | Air Gap Adaptor Fitting, 8\"–10\" Backflow Preventers","description":"\u003cp\u003e\nThe Wilkins AG-14 is an air gap adaptor fitting designed for use with large diameter Reduced Pressure Principle Backflow Preventers on horizontal or vertical installations.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 8\"–10\" compatibility range\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eOutlet Connection:\u003c\/strong\u003e 4\" NPT outlet\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ANSI\/ASME A 112.1.2\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eApproximate Dimensions:\u003c\/strong\u003e 7\" A, 16 1\/2\" B\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 11 lbs (5 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-4:\u003c\/strong\u003e 3\/4\"–1\" and 1 1\/4\"–1 1\/2\" model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-5:\u003c\/strong\u003e 1 1\/4\"–2\" model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-6:\u003c\/strong\u003e 2 1\/2\"–6\" model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-7:\u003c\/strong\u003e 8\"–10\" model size (375\/475 series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-8:\u003c\/strong\u003e 1\/4\"–1\/2\" and 1\/2\"–1\" model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-9:\u003c\/strong\u003e 4\"–6\" model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-10:\u003c\/strong\u003e 8\"–10\" model size (475V series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-11:\u003c\/strong\u003e 1\/2\"–1\" model size with 2\" IPS Slip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-12:\u003c\/strong\u003e 1 1\/4\"–2\" model size with 3\" IPS Slip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAG-13:\u003c\/strong\u003e 4\"–6\" model size (475ST\/475STV series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody: Cast grey iron, epoxy painted\u003c\/li\u003e\n\u003cli\u003eElbow: Cast grey iron, epoxy painted\u003c\/li\u003e\n\u003cli\u003eBolts: Steel, zinc plated\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nANSI\/ASME A 112.1.2\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Air Gap Protection:\u003c\/strong\u003e Provides necessary air gap when installing a drain line on Reduced Pressure Principle Backflow Preventers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Installation:\u003c\/strong\u003e Compatible with horizontal or vertical installations for maximum flexibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody-Mounted Design:\u003c\/strong\u003e Can be mounted directly to the backflow preventer body for streamlined installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Epoxy painted cast grey iron body resists corrosion for long-lasting performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What backflow preventer series is the Zurn AG-14 compatible with?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn AG-14 is designed specifically for use with 8\"–10\" 475ST and 475STV series Reduced Pressure Principle Backflow Preventers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What type of drain line can be used with the Wilkins AG-14?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The drain line can be any standard piping material, providing flexibility in installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the AG-14 be used for both horizontal and vertical installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the AG-14 is designed for use with both horizontal and vertical backflow preventer installations.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42983791919167,"sku":"AG-14","price":466.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/AG-14_AF.jpg?v=1772854829","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-ag-14-air-gap-adaptor-fitting-810-backflow-preventers","provider":"BottleFillingStations.com","version":"1.0","type":"link"}