{"product_id":"wilkins-6-zw209-pilot-operated-pressure-reducing-valve","title":"Wilkins 6-ZW209 | Pilot Operated Pressure Reducing Valve","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 6-ZW209 is a pilot operated pressure reducing valve designed to reduce high inlet pressures to safe, stable outlet pressures in commercial and industrial water systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Size:\u003c\/strong\u003e 6 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e ANSI Class 150, 250 psi max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e 33°F to 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e NSF\/ANSI\/CAN 61 compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot Adjustable Range:\u003c\/strong\u003e 15–120 psi\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e212-ZW209:\u003c\/strong\u003e 2 1\/2 Inches valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-ZW209:\u003c\/strong\u003e 2 Inches valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-ZW209:\u003c\/strong\u003e 3 Inches valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-ZW209:\u003c\/strong\u003e 4 Inches valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-ZW209:\u003c\/strong\u003e 8 Inches valve size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Ductile Iron ASTM A536\u003c\/li\u003e\n\u003cli\u003eMain Valve Bonnet: Ductile Iron ASTM A536\u003c\/li\u003e\n\u003cli\u003eDisc Guide: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eDisc: Buna-N Rubber\u003c\/li\u003e\n\u003cli\u003eDiaphragm: Nylon Reinforced Buna-N\u003c\/li\u003e\n\u003cli\u003eStem: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSpring: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eFusion Epoxy Coating (internal and external)\u003c\/li\u003e\n\u003cli\u003eCopper Tubing and Brass Fittings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eThe recommended installation orientation for the Zurn 6-ZW209 is horizontal with the valve cover up. 6 Inches and larger valves should only be installed horizontally with the valve cover up due to the difficulty of properly bleeding air out of the cover and performing maintenance on valves installed in the vertical orientation. The valve should be installed with inlet and outlet shut-off valves for proper system control.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eANSI\/AWWA C530; NSF\/ANSI\/CAN 61 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Pressure Regulation:\u003c\/strong\u003e Pilot assembly reacts to downstream pressure changes ensuring constant outlet pressure regardless of flow rate or inlet pressure variations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e FDA-approved fusion epoxy coating on all internal and external surfaces provides superior durability and long service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance:\u003c\/strong\u003e Includes standard isolation valves and inlet\/outlet pressure gauges for quick troubleshooting, adjustment, and repair without system shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Assembly:\u003c\/strong\u003e Comes with wye strainer, opening speed control, pilot assembly, and all necessary components for immediate installation and operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum inlet pressure required for the Wilkins 6-ZW209?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The minimum inlet pressure is 10 psi higher than the set point or the additional body friction loss at intended flow, whichever is higher.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the outlet pressure be adjusted on the Zurn 6-ZW209?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the pilot assembly is field adjustable from 15 psi to 120 psi, allowing for precise control of downstream pressure to meet specific application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What components are included with the valve for maintenance purposes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The valve comes standard with isolation valves on both inlet and outlet sides, inlet and outlet pressure gauges, a wye-type strainer, and a pilot assembly with all necessary copper tubing and brass fittings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42983791132735,"sku":"6-ZW209","price":9039.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/ZW209_AL_4b0e9487-f377-423d-9ff1-6845a1de1cd8.png?v=1772854791","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-6-zw209-pilot-operated-pressure-reducing-valve","provider":"BottleFillingStations.com","version":"1.0","type":"link"}