{"product_id":"wilkins-38-zw1070xlcomp-thermostatic-mixing-valve-point-of-use-scald-protection","title":"Wilkins 38-ZW1070XLCOMP | Thermostatic Mixing Valve, Point-of-Use Scald Protection","description":"\u003cp\u003e\nThe Wilkins 38-ZW1070XLCOMP is an Aqua-Gard® thermostatic mixing valve designed for point-of-use scald protection with rapid response rate for safe water temperature control.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/8 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 125 psi inlet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Temperature Range:\u003c\/strong\u003e 95–115°F maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1070, cUPC Listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Compression connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-ZW1070XL:\u003c\/strong\u003e 1\/2 Inch FNPT model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-ZW1070XLC:\u003c\/strong\u003e 1\/2 Inch CU Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-ZW1070XLCPVC:\u003c\/strong\u003e 1\/2 Inch CPVC version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-ZW1070XLPEX:\u003c\/strong\u003e 1\/2 Inch Barb connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-ZW1070XLPEXF1960:\u003c\/strong\u003e 1\/2 Inch Barb alternative\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-ZW1070XLPF:\u003c\/strong\u003e 1\/2 Inch push fit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-ZW1070XLC:\u003c\/strong\u003e 1 Inch CU Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-ZW1070XL:\u003c\/strong\u003e 3\/4 Inch FNPT model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-ZW1070XLCOMP:\u003c\/strong\u003e 3\/4 Inch Compression version\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody: Low Lead Cast Bronze, ASTM B 584 with Chrome Plating ASTM B 456 Service Condition #2\u003c\/li\u003e\n\u003cli\u003eInternal Brass: Low Lead Brass, ASTM B 927, UNS C27450\u003c\/li\u003e\n\u003cli\u003ePiston: Polysufone\u003c\/li\u003e\n\u003cli\u003eGuide Tube: Noryl GFN2\u003c\/li\u003e\n\u003cli\u003eSpring and Screen: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSeals: Viton\u003c\/li\u003e\n\u003cli\u003eChecks: Noryl GFN2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nThe Zurn 38-ZW1070XLCOMP is ideal for point-of-use installation at plumbing fixtures and appliances requiring final control of water temperature. Suitable for individual use applications including sinks, lavatories, bathtubs, and sensor faucets. The device is designed to be installed at a single outlet and may supply individual outlets when sufficient supply pressure is available. Ball valves on hot and cold inlet supplies are recommended.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1070; cUPC Listed; CSA Certified B125.70; NSF\/ANSI\/CAN 61-9 Q≤1 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScald Protection:\u003c\/strong\u003e Mixes hot and cold water to a safer final temperature of 95-115°F, preventing scalding injuries at point of use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Response Rate:\u003c\/strong\u003e Extremely fast temperature adjustment makes it ideal for installation at fixtures and appliances requiring immediate temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 61-9 standards with 0.25% maximum weighted average lead content for safe drinking water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Configurations:\u003c\/strong\u003e Multiple end connection options available to suit all residential and commercial installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum pressure differential allowed between hot and cold inlets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The maximum pressure differential is 15 psi between the hot and cold water inlets for proper operation of the Wilkins 38-ZW1070XLCOMP.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the temperature need to be adjusted after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the temperature must be field set during installation. The set temperature accuracy is +\/- 3°F (1.78°C) within the 95-115°F outlet range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum flow rate required for this valve to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn 38-ZW1070XLCOMP has a minimum flow rate of 0.25 gpm and can handle up to 10 gpm at 45 psi pressure loss.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42983790903359,"sku":"38-ZW1070XLCOMP","price":296.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/38-ZW1070XLCOMP_F.jpg?v=1772854740","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-38-zw1070xlcomp-thermostatic-mixing-valve-point-of-use-scald-protection","provider":"BottleFillingStations.com","version":"1.0","type":"link"}