{"product_id":"wilkins-34-975xlft-34-rp-backflow-preventer-with-flare-test-fittings","title":"Wilkins 34-975XLFT | 3\/4\" RP Backflow Preventer with Flare Test Fittings","description":"\u003cp\u003e\nThe Wilkins 34-975XLFT is a reduced pressure principle backflow prevention assembly designed for non-potable applications, featuring integral male 45° flare SAE test fittings and full port QT ball valves for reliable protection.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4 Inches\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 175 psi\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Integral Male 45° Flare SAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-975XLFT:\u003c\/strong\u003e 1 1\/2 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XLFT:\u003c\/strong\u003e 1 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-975XLFT:\u003c\/strong\u003e 2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody: Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eFasteners: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone\/Buna Nitrile\u003c\/li\u003e\n\u003cli\u003eSprings: 300 Series Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nThe assembly shall be mounted at a minimum of 12 inches above the highest piping or outlet downstream of the device. Install with adequate drain and sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1013; cUPC; UL\/C-UL Classified; CSA B64.4; AWWA C511; NYC MEA 425-89-M VOL 3\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Test Fittings:\u003c\/strong\u003e Built-in male 45° flare SAE test fittings simplify testing and maintenance procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Design:\u003c\/strong\u003e QT ball valves provide maximum flow capacity and minimal pressure loss for optimal system performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Cast bronze body with stainless steel components ensures long-lasting reliability in demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Agency Approval:\u003c\/strong\u003e Certified to multiple standards including ASSE 1013, cUPC, and CSA B64.4 for broad application acceptance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum installation height required for the Zurn 34-975XLFT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be installed 12 inches to 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this backflow preventer be used for potable water applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the Zurn 34-975XLFT is designed for non-potable applications only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is an air gap adapter required for all installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For indoor installations, an air gap adapter is required. The unit must not be submerged in any installation configuration.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914906570815,"sku":"34-975XLFT","price":768.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/34-975XLFT_AF.jpg?v=1771002886","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-34-975xlft-34-rp-backflow-preventer-with-flare-test-fittings","provider":"BottleFillingStations.com","version":"1.0","type":"link"}