{"product_id":"wilkins-34-975xl2tcu-reduced-pressure-backflow-assembly-34-inches","title":"Wilkins 34-975XL2TCU | Reduced Pressure Backflow Assembly, 3\/4 Inches","description":"\u003cp\u003e\nThe Wilkins 34-975XL2TCU is a Reduced Pressure Principle backflow preventer designed for potable water lines, protecting against backsiphonage and backpressure where health hazards exist.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2TCU:\u003c\/strong\u003e 1 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-975XL2TCU:\u003c\/strong\u003e 2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, the installation shall be supplied with an air gap adapter.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1013; cUPC; CSA B64.4; AWWA C511; UL\/C-UL Classified; NSF\/ANSI\/CAN 61 \u0026amp; 372; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides protection where a potential health hazard exists, safeguarding potable water supply from contaminated water backflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Low lead cast bronze construction meets NSF\/ANSI\/CAN 61 and 372 requirements with less than 0.25% weighted average lead content.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Ball Valves:\u003c\/strong\u003e Equipped with full port QT ball valves for optimal flow and test cocks up configuration for convenient testing and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Materials:\u003c\/strong\u003e Features 300 Series stainless steel fasteners, springs, and handles with silicone and buna nitrile elastomers for long-lasting performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the proper installation height for the Zurn 34-975XL2TCU backflow preventer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is an air gap fitting required for the Zurn 34-975XL2TCU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, for indoor installations, an air gap adapter must be supplied. The installation must be made so that no part of the unit can be submerged.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What type of water supply lines is the Wilkins 34-975XL2TCU suitable for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Wilkins 34-975XL2TCU is designed for installation on potable water lines to protect against both backsiphonage and backpressure where a potential health hazard exists.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914906374207,"sku":"34-975XL2TCU","price":1183.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/34-975XL2TCU_F.jpg?v=1771002893","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-34-975xl2tcu-reduced-pressure-backflow-assembly-34-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}