{"product_id":"wilkins-34-600xlluchsc-34-water-pressure-reducing-valve","title":"Wilkins 34-600XLLUCHSC | 3\/4\" Water Pressure Reducing Valve","description":"\u003cp\u003e\nThe Wilkins 34-600XLLUCHSC is a water pressure reducing valve designed for potable water systems, featuring chrome plated stem and sealed cage construction for enhanced durability and reliability.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, CSA B356, NSF\/ANSI\/CAN 61 \u0026amp; 372\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Female FNPT threaded\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-600XLLU:\u003c\/strong\u003e Standard configuration without chrome plating and sealed cage options\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody: Low Lead Cast Bronze\u003c\/li\u003e\n\u003cli\u003eBell Housing: Glass Reinforced Nylon\u003c\/li\u003e\n\u003cli\u003eStem and Plunger: Chrome Plated\u003c\/li\u003e\n\u003cli\u003eInternal Components: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile and EPDM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nThe valve may be installed in any position on threaded piping systems. Local codes shall govern installation requirements. If installed in a pit, vault or inside application, the sealed cage option is recommended. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1. A pressure gauge must be used downstream to verify correct pressure setting during adjustment.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1003; CSA B356; NSF\/ANSI\/CAN 61 \u0026amp; 372; IAPMO Listed\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed Cage Design:\u003c\/strong\u003e Improves reliability and durability in demanding applications including pit and vault installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChrome Plated Components:\u003c\/strong\u003e Chrome plated stem and plunger with stainless steel trim provide enhanced corrosion resistance and longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Enables smooth and responsive reaction to changes in system flow demand while providing protection from inlet pressure changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess Union Configuration:\u003c\/strong\u003e Designed for easy retrofit installations allowing use of existing union assemblies for convenient servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the factory preset pressure setting for the Zurn 34-600XLLUCHSC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The valve is factory preset at 50 psi with an adjustable spring range of 25 psi to 75 psi.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins 34-600XLLUCHSC be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, this valve may be installed in any position on threaded piping systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"LU\" option indicate in the model number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"LU\" designation indicates a less union configuration, which allows the valve to be installed using existing union nuts and tailpieces for replacement applications.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42934987161663,"sku":"34-600XLLUCHSC","price":512.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/34-600XLLUCHSC_R_783fe555-5acd-4fc9-b2c2-3b30079898ce.jpg?v=1771501969","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-34-600xlluchsc-34-water-pressure-reducing-valve","provider":"BottleFillingStations.com","version":"1.0","type":"link"}