{"product_id":"wilkins-34-600xldm-water-pressure-reducing-valve-with-meter-connection","title":"Wilkins 34-600XLDM | Water Pressure Reducing Valve with Meter Connection","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 34-600XLDM is a water pressure reducing valve with integral by-pass check valve, direct male meter connection, and strainer designed for reliable pressure control in potable water systems requiring lead-free compliance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, IAPMO, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Male Meter Thread\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eFasteners: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eStem \u0026amp; Plunger: Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile, FDA; EPDM, FDA\u003c\/li\u003e\n\u003cli\u003eCap Gaskets: Delrin™ 500 Acetal, NSF Listed\u003c\/li\u003e\n\u003cli\u003eStrainer Screen: 300 Series Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The Zurn 34-600XLDM may be installed in any position. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). Designed for meter setter installations with direct male meter thread connections specifically designed for meter setter applications. The direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1003; IAPMO Listed; CSA Certified; City of Los Angeles Approved; NSF\/ANSI 372; NSF\/ANSI\/CAN 61\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Enables smooth and responsive reaction to system flow demand changes while providing protection from inlet pressure changes in both flow and no-flow conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral By-Pass Check Valve:\u003c\/strong\u003e Direct acting design prevents buildup of excessive system pressure caused by thermal expansion, eliminating the need for separate thermal expansion tanks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Certified to NSF\/ANSI 372 with 0.25% maximum weighted average lead content, ideal for potable water applications where lead-free valves are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter Connection Ready:\u003c\/strong\u003e Double male meter thread connections specifically designed for meter setter applications simplify installation and reduce required fittings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the Zurn 34-600XLDM be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the valve may be installed in any position, providing flexibility for various installation configurations and space constraints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the factory preset pressure setting and adjustment range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The valve comes factory set at 50 psi with a standard adjustment range of 25 psi to 75 psi. A high range option (HR) is available for 75 psi to 125 psi applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: When should multiple valves be installed in series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 ratio (for example: 200 psi inlet reduced to 50 psi outlet).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42934987128895,"sku":"34-600XLDM","price":519.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/600XLDM_AF.png?v=1771501964","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-34-600xldm-water-pressure-reducing-valve-with-meter-connection","provider":"BottleFillingStations.com","version":"1.0","type":"link"}