{"product_id":"wilkins-34-500xlhlr-water-pressure-reducing-valve-with-integral-by-pass-check","title":"Wilkins 34-500XLHLR | Water Pressure Reducing Valve with Integral By-pass Check","description":"\u003cp\u003e\nThe Wilkins 34-500XLHLR is a water pressure reducing valve with integral by-pass check valve, designed to reduce high inlet pressure to a lower outlet pressure for commercial and industrial water systems.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4 Inches\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 300 psi\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 140°F\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, cUPC, CSA B356\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eConnection Type:\u003c\/strong\u003e Single Union FNPT\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e112-500XLHLR:\u003c\/strong\u003e 1 1\/2 Inches size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e114-500XLHLR:\u003c\/strong\u003e 1 1\/4 Inches size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e1-500XLHLR:\u003c\/strong\u003e 1 Inches size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e2-500XLHLR:\u003c\/strong\u003e 2 Inches size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e3-500XLHLR:\u003c\/strong\u003e 3 Inches size\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eBody: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n  \u003cli\u003eAccess Covers: Low Lead Brass\u003c\/li\u003e\n  \u003cli\u003eFasteners: Stainless Steel, 300 series\u003c\/li\u003e\n  \u003cli\u003eStem \u0026amp; Plunger: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n  \u003cli\u003eElastomers: Buna Nitrile (FDA approved)\u003c\/li\u003e\n  \u003cli\u003eElastomers: EPDM (FDA approved)\u003c\/li\u003e\n  \u003cli\u003eCap Gaskets: Natural Vulcanized Fibre\u003c\/li\u003e\n  \u003cli\u003eCap Gaskets: Acetal (Delrin 500)\u003c\/li\u003e\n  \u003cli\u003eSprings: Oil Tempered Wire, ASTM A 229\u003c\/li\u003e\n  \u003cli\u003eSeat: Stainless Steel, 300 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Zurn 34-500XLHLR may be installed in any position. If installed in a pit, vault, or inside application, specify the \"SC\" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 3 to 1 (i.e.: 150 psi inlet reduced to 50 psi outlet).\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1003; cUPC Listed; CSA Certified B356; City of Los Angeles Approved; NSF\/ANSI\/CAN 61; NSF\/ANSI\/CAN 372\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Flow Capacity:\u003c\/strong\u003e Balanced piston design provides smooth and responsive pressure regulation for industrial and commercial water systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Expansion Protection:\u003c\/strong\u003e Direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Can be installed in any position with side clearance for maintenance, suitable for various applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Pressure Range:\u003c\/strong\u003e HLR option offers 10 psi to 125 psi spring range, factory set at 50 psi for versatile applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins 34-500XLHLR be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Model 500XL may be installed in any position. If installed in a pit, vault, or inside application, specify the \"SC\" sealed cage option.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the recommended pressure reduction ratio for this valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Multiple installations are recommended where the desired pressure reduction is more than 3 to 1 (for example: 150 psi inlet reduced to 50 psi outlet).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I adjust the pressure setting on the Zurn 34-500XLHLR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom the adjustment bolt on bell housing.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n  \u003cp\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003eNOTICE:\u003c\/strong\u003e\n      Do not use with water that is unsafe or of unknown quality without adequate\n      disinfection either before or after the system.\n    \u003c\/span\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n  \u003ci\u003e\n    \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n    \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\n      Contact us\n    \u003c\/a\u003e\n  \u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914904277055,"sku":"34-500XLHLR","price":594.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/34-500XLHLR_AF.jpg?v=1771002914","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-34-500xlhlr-water-pressure-reducing-valve-with-integral-by-pass-check","provider":"BottleFillingStations.com","version":"1.0","type":"link"}