{"product_id":"wilkins-2-zw209bp-pilot-operated-prv-with-low-flow-by-pass-2-inches","title":"Wilkins 2-ZW209BP | Pilot Operated PRV with Low Flow By-Pass, 2 Inches","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 2-ZW209BP is a pilot-operated pressure reducing valve with integrated low-flow bypass, designed to maintain stable outlet pressure while handling flows from 1-10 GPM during off-peak demand periods.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e ANSI Class 150, 250 psi max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e 33°F to 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e NSF\/ANSI\/CAN 61; ANSI\/AWWA C530\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Flanged ANSI Class 150\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-ZW209BP:\u003c\/strong\u003e 1 1\/2 Inches valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e212-ZW209BP:\u003c\/strong\u003e 2 1\/2 Inches valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-ZW209BP:\u003c\/strong\u003e 3 Inches valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-ZW209BP:\u003c\/strong\u003e 4 Inches valve size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Ductile Iron ASTM A536\u003c\/li\u003e\n\u003cli\u003eMain Valve Bonnet: Ductile Iron ASTM A536\u003c\/li\u003e\n\u003cli\u003eDisc Guide: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eDisc: Buna-N Rubber\u003c\/li\u003e\n\u003cli\u003eDiaphragm: Nylon Reinforced Buna-N\u003c\/li\u003e\n\u003cli\u003eStem: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSpring: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eCopper Tubing and Brass Fittings\u003c\/li\u003e\n\u003cli\u003eBlue Epoxy Coating (FDA Approved)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eThe Zurn 2-ZW209BP is commonly used in buildings where 1-15 GPM low flows are common during off-peak usage. Applications include commercial buildings, residential high-rise systems, and any installation requiring reduction of high inlet pressures to safe and stable outlet pressure with low-flow bypass capability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eANSI\/AWWA C530; NSF\/ANSI\/CAN 61 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Low-Flow Bypass:\u003c\/strong\u003e Handles flows up to 10 GPM during off-peak demand without requiring main valve operation, extending valve life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Control System:\u003c\/strong\u003e Includes wye strainer, isolation valves, inlet\/outlet pressure gauges, and pilot assembly for simplified installation and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Blue epoxy-coated ductile iron body with stainless steel trim provides corrosion protection and long service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Pressure Control:\u003c\/strong\u003e Pilot adjustable range of 15-120 psi allows precise downstream pressure regulation for various applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum inlet pressure required for the Wilkins 2-ZW209BP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The minimum inlet pressure is 10 psi higher than the set point or the additional body friction loss at intended flow, whichever is higher.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the Zurn 2-ZW209BP eliminate the need for additional low-flow bypass valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Not in all cases. While the integrated bypass handles 1-10 GPM, an additional bypass valve may be needed to bridge the gap between the bypass maximum flow and the main valve minimum continuous flow (15 GPM for 2 inch size).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the recommended installation orientation for this valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The recommended installation orientation is horizontal with the valve cover up for proper operation and maintenance access.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42983789822015,"sku":"2-ZW209BP","price":5081.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/ZW209BP_AL_2e11ebde-70b2-462c-a11d-9a00313ab1ef.png?v=1772854648","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-zw209bp-pilot-operated-prv-with-low-flow-by-pass-2-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}