{"product_id":"wilkins-2-975xl3s-reduced-pressure-backflow-assembly-2-inches","title":"Wilkins 2-975XL3S | Reduced Pressure Backflow Assembly, 2 Inches","description":"\u003cp\u003e\nThe Wilkins 2-975XL3S is a 2 Inches reduced pressure principle backflow prevention assembly designed to protect potable water supplies from contamination where potential health hazards exist.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded FNPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\/2-975XL3S:\u003c\/strong\u003e 1\/2 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\/4-975XL3S:\u003c\/strong\u003e 3\/4 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL3S:\u003c\/strong\u003e 1 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 1\/4-975XL3S:\u003c\/strong\u003e 1 1\/4 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 1\/2-975XL3S:\u003c\/strong\u003e 1 1\/2 Inches version\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow Lead Cast Bronze ASTM B584 (Body and Access Covers)\u003c\/li\u003e\n\u003cli\u003e300 Series Stainless Steel (Fasteners and Springs)\u003c\/li\u003e\n\u003cli\u003eSilicone FDA Approved (Elastomers)\u003c\/li\u003e\n\u003cli\u003eBuna Nitrile FDA Approved (Elastomers)\u003c\/li\u003e\n\u003cli\u003eNoryl™ (Polymers)\u003c\/li\u003e\n\u003cli\u003eStainless Steel (Ball Valve Handles)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1013; cUPC; CSA B64.4; UL Classified; C-UL Classified; AWWA C511; NSF\/ANSI\/CAN 61; NSF\/ANSI\/CAN 372; Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides reliable protection against both backsiphonage and backpressure of contaminated water into potable water supply systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 372 with less than 0.25% weighted average lead content, ideal for safe potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks accessible for maintenance without removing relief valve or entire device from the line, sharing a single access cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Design:\u003c\/strong\u003e Features low lead cast bronze body, stainless steel fasteners and springs, and FDA approved silicone elastomers for long-lasting performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum working pressure required for the Zurn 2-975XL3S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn 2-975XL3S requires a minimum working water pressure of 25 PSI and can handle a maximum of 175 PSI.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: At what height should the Wilkins 2-975XL3S be installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly should be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this backflow preventer be submerged during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the installation must be made so that no part of the unit can be submerged to ensure proper operation and compliance.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914899591231,"sku":"2-975XL3S","price":2302.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/2-975XL3S_AF.jpg?v=1771002941","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-975xl3s-reduced-pressure-backflow-assembly-2-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}