{"product_id":"wilkins-2-975xl3ns-reduced-pressure-backflow-preventer-n-pattern","title":"Wilkins 2-975XL3NS | Reduced Pressure Backflow Preventer, N-Pattern","description":"\u003cp\u003e\nThe Wilkins 2-975XL3NS protects potable water from backflow and backpressure contamination with a lead-free, N-Pattern design.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2 Inches\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e175 PSI\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Working Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e180°F\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eNotable Certifications\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eASSE 1013; AWWA C511; CSA B64.4; cUPC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eThreaded FNPT (ANSI B1.20.1)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e112-975XL3NS:\u003c\/strong\u003e 1 1\/2 Inches version\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1-975XL3NS:\u003c\/strong\u003e 1 Inches version\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e34-975XL3NS:\u003c\/strong\u003e 3\/4 Inches version\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLow Lead Cast Bronze ASTM B584 (Access Cover)\u003c\/li\u003e\n  \u003cli\u003eLow Lead Cast Bronze ASTM B584 (Main Valve Body)\u003c\/li\u003e\n  \u003cli\u003eStainless Steel (Ball Valve Handles)\u003c\/li\u003e\n  \u003cli\u003eBuna Nitrile, FDA Approved (Elastomers)\u003c\/li\u003e\n  \u003cli\u003eEPDM, FDA Approved (Elastomers)\u003c\/li\u003e\n  \u003cli\u003eSilicone, FDA Approved (Elastomers)\u003c\/li\u003e\n  \u003cli\u003e300 Series Stainless Steel (Fasteners)\u003c\/li\u003e\n  \u003cli\u003eNORYL™ (Polymers)\u003c\/li\u003e\n  \u003cli\u003e300 Series Stainless Steel (Springs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. The unit is to be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1013; AWWA Compliant C511; CSA Certified B64.4; cUPC Listed; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets the requirements of NSF\/ANSI\/CAN 61 \u0026amp; 372\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Meets low-lead requirements with less than 0.25% weighted average lead content for safe potable water use.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncluded Strainer:\u003c\/strong\u003e Bronze \"Y\" type strainer helps protect internal components from debris for reliable long-term operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy Maintenance:\u003c\/strong\u003e First and second checks are accessible for servicing without removing the relief valve or entire device from the line.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Flow Orientation:\u003c\/strong\u003e N-Pattern design supports both vertical flow up and vertical flow down installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What size is the Wilkins 2-975XL3NS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Wilkins 2-975XL3NS is a 2 Inches Reduced Pressure Principle Backflow Preventer.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the Zurn 2-975XL3NS include a strainer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the \"S\" suffix indicates it includes a Bronze \"Y\" type strainer for added protection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum operating temperature for this valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit is rated for a maximum working water temperature of 180°F.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n  \u003cp\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003eNOTICE:\u003c\/strong\u003e\n      Do not use with water that is unsafe or of unknown quality without adequate\n      disinfection either before or after the system.\n    \u003c\/span\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n  \u003ci\u003e\n    \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n    \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\n      Contact us\n    \u003c\/a\u003e\n  \u003c\/i\u003e\n\u003c\/p\u003e","brand":"Elkay","offers":[{"title":"Default Title","offer_id":43800718278719,"sku":"2-975XL3NS","price":2753.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/2-975XL3N_R_RDR_69936894-4126-4c2d-a343-f0097f1c7d28.jpg?v=1787816283","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-975xl3ns-reduced-pressure-backflow-preventer-n-pattern","provider":"BottleFillingStations.com","version":"1.0","type":"link"}