{"product_id":"wilkins-2-975xl2tcusag-2-backflow-preventer-with-strainer-air-gap","title":"Wilkins 2-975XL2TCUSAG | 2\" Backflow Preventer with Strainer \u0026 Air Gap","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 2-975XL2TCUSAG is a Reduced Pressure Principle Backflow Prevention Assembly designed to protect potable water lines from contamination where health hazards exist.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-975XL2TCUSAG:\u003c\/strong\u003e 1 1\/2 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2TCUSAG:\u003c\/strong\u003e 1 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-975XL2TCUSAG:\u003c\/strong\u003e 3\/4 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone and Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, an air gap adapter is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE 1013; cUPC; CSA B64.4; AWWA C511; NSF\/ANSI\/CAN 61 \u0026amp; 372; UL\/C-UL Classified; Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides protection against both backsiphonage and backpressure of contaminated water into potable water supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 61 and 372 standards with less than 0.25% weighted average lead content for safe drinking water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Package:\u003c\/strong\u003e Includes Test Cocks Up (TCU), Bronze Y-Type Strainer (S), and Air Gap Accessory (AG) for comprehensive installation needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the required installation height for the Zurn 2-975XL2TCUSAG?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the air gap fitting required for all installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The included air gap fitting (AG) is required for indoor installations to prevent submersion of the unit. Installation must be made so no part of the unit can be submerged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the maximum operating conditions for this backflow preventer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn 2-975XL2TCUSAG has a maximum working water pressure of 175 PSI and maximum working water temperature of 180°F, with a hydrostatic test pressure of 350 PSI.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914899099711,"sku":"2-975XL2TCUSAG","price":2909.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/114_2-975XL2_AL_e5ba714a-fdcb-4b47-845f-6551c6844153.png?v=1770568316","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-975xl2tcusag-2-backflow-preventer-with-strainer-air-gap","provider":"BottleFillingStations.com","version":"1.0","type":"link"}