{"product_id":"wilkins-2-975xl2seu-reduced-pressure-backflow-preventer-2-inches","title":"Wilkins 2-975XL2SEU | Reduced Pressure Backflow Preventer, 2 Inches","description":"\u003cp\u003e\nThe Wilkins 2-975XL2SEU is a Reduced Pressure Principle Backflow Prevention Assembly designed to protect potable water lines from contamination.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-975XL2SEU:\u003c\/strong\u003e 1 1\/2 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-975XL2SEU:\u003c\/strong\u003e 1 1\/4 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2SEU:\u003c\/strong\u003e 1 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-975XL2SEU:\u003c\/strong\u003e 3\/4 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, the installation shall be supplied with an air gap adapter.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1013; cUPC; CSA B64.4; AWWA C511; UL\/C-UL Classified; NSF\/ANSI\/CAN 61 \u0026amp; 372; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Protects against both backsiphonage and backpressure of contaminated water into potable water supply where a potential health hazard exists.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 61 and 372 standards with less than 0.25% weighted average lead content for safe drinking water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Flood Detection:\u003c\/strong\u003e Can be configured with a relief valve sensor that detects and signals excessive water discharge to prevent property damage from flooding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the proper installation height for the Zurn 2-975XL2SEU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this backflow preventer be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Wilkins 2-975XL2SEU can be installed outdoors. However, a protective enclosure is recommended, and proper drainage must be provided.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What options are available with the 2-975XL2SEU model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Options include union ball valves (U suffix), street elbows (SE suffix for 3\/4\" \u0026amp; 1\" sizes), test cocks up (TCU), integral male 45° flare SAE test fitting (FT), bronze \"Y\" type strainer (S), and relief valve excessive discharge sensor for flood detection (MS).\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914898673727,"sku":"2-975XL2SEU","price":2886.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/2-975XL2SEU_AF.jpg?v=1771002942","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-975xl2seu-reduced-pressure-backflow-preventer-2-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}