{"product_id":"wilkins-2-975xl2sag-2-rp-backflow-preventer-with-strainer-air-gap","title":"Wilkins 2-975XL2SAG | 2\" RP Backflow Preventer with Strainer \u0026 Air Gap","description":"\u003cp\u003e\nThe Wilkins 2-975XL2SAG is a reduced pressure principle backflow prevention assembly designed to protect potable water supplies from contamination where a potential health hazard exists.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\/4-975XL2SAG:\u003c\/strong\u003e 3\/4 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2SAG:\u003c\/strong\u003e 1 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 1\/4-975XL2SAG:\u003c\/strong\u003e 1 1\/4 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 1\/2-975XL2SAG:\u003c\/strong\u003e 1 1\/2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone and Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall valve handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, the included air gap fitting is required.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets the requirements of NSF\/ANSI\/CAN 61 and 372; UL Classified; C-UL Classified\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides protection against both backsiphonage and backpressure of contaminated water into potable water supply where a potential health hazard exists.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 61 and 372 standards with less than 0.25% weighted average lead content, ideal for use where lead-free valves are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line, simplifying service procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Bronze Y-Type Strainer and Air Gap:\u003c\/strong\u003e The Zurn 2-975XL2SAG comes equipped with a bronze Y-type strainer for filtration and an air gap accessory required for indoor installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the required installation height for the Zurn 2-975XL2SAG?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the air gap accessory required for all installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The included air gap fitting is required for indoor installations. The installation must be made so that no part of the unit can be submerged.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What type of valves are included with this assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit comes standard with full port QT ball valves, providing reliable shut-off capability for maintenance and testing.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914898411583,"sku":"2-975XL2SAG","price":2804.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/2-975XL2SAG_AF.jpg?v=1771002945","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-975xl2sag-2-rp-backflow-preventer-with-strainer-air-gap","provider":"BottleFillingStations.com","version":"1.0","type":"link"}