{"product_id":"wilkins-2-950xl3ft-2-reduced-pressure-principle-backflow-preventer","title":"Wilkins 2-950XL3FT | 2\" Reduced Pressure Principle Backflow Preventer","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 2-950XL3FT is a 2-inch Reduced Pressure Principle Backflow Prevention Assembly designed to protect potable water supplies from contamination.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking Pressure:\u003c\/strong\u003e 25 to 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 180°F (82°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded FNPT ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-950XL3FT:\u003c\/strong\u003e 1 1\/2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eFasteners: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA Approved)\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eBall valve handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1013; cUPC Listed; CSA Certified B64.4; UL Classified (less shut-off valves); C-UL Classified; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets NSF\/ANSI\/CAN 61 and 372\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Ideal for use where Lead-Free valves are required, meeting NSF\/ANSI\/CAN 61 and 372 standards with less than 0.25% weighted average lead content.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Protection:\u003c\/strong\u003e Protects against both backsiphonage and backpressure of contaminated water where a potential health hazard exists.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Low lead bronze body with 300 Series stainless steel fasteners and springs ensures long-lasting performance in demanding applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum working pressure for the Zurn 2-950XL3FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn 2-950XL3FT requires a minimum working water pressure of 25 PSI and supports up to 175 PSI maximum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this backflow preventer be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 inches and maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance, and no part of the unit can be submerged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of valves are included with this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit comes standard with full port ball valves, and the 2-inch size with FT suffix includes integral male 45° flare SAE test fittings (requires factory approval).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914896085055,"sku":"2-950XL3FT","price":1442.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/1-975XL3_F_9db5765e-d00e-45cd-91ea-203c0b597b50.png?v=1770568264","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-950xl3ft-2-reduced-pressure-principle-backflow-preventer","provider":"BottleFillingStations.com","version":"1.0","type":"link"}