{"product_id":"wilkins-2-600xl-water-pressure-reducing-valve-with-by-pass-strainer","title":"Wilkins 2-600XL | Water Pressure Reducing Valve with By-pass \u0026 Strainer","description":"\u003cp\u003eThe Wilkins 2-600XL is a water pressure reducing valve designed for residential and commercial potable water systems, featuring an integral by-pass check valve and strainer to reduce high inlet pressure while preventing thermal expansion buildup.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, IAPMO, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Single Union\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/wilkins-12-600xl-water-pressure-reducing-valve-with-integral-by-pass\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e12-600XL:\u003c\/strong\u003e\u003c\/a\u003e 1\/2 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/wilkins-34-600xl-water-pressure-reducing-valve-with-by-pass-check-strainer\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e34-600XL:\u003c\/strong\u003e\u003c\/a\u003e 3\/4 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-1-600xl-water-pressure-reducing-valve-with-by-pass-strainer\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e1-600XL:\u003c\/strong\u003e \u003c\/a\u003e1 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/wilkins-114-600xl-pressure-reducing-valve-with-by-pass-strainer\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e114-600XL:\u003c\/strong\u003e\u003c\/a\u003e 1 1\/4 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/wilkins-112-600xl-water-pressure-reducing-valve-with-integral-by-pass-strainer\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e112-600XL:\u003c\/strong\u003e \u003c\/a\u003e1 1\/2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eStem \u0026amp; plunger: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA Approved) \/ EPDM (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eCap gaskets: Natural Vulcanized Fibre \/ Acetal (Delrin™)\u003c\/li\u003e\n\u003cli\u003eStrainer screen: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The Model 600XL may be installed in any position. If installed in a pit, vault or inside application, specify the \"SC\" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1003; IAPMO Listed; CSA Certified; City of Los Angeles Approved; NSF\/ANSI\/CAN 61\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral By-pass Check Valve:\u003c\/strong\u003e Prevents buildup of excessive system pressure caused by thermal expansion in the water system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Ensures smooth and responsive reaction to changes in system flow demand while providing protection from inlet pressure changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Strainer:\u003c\/strong\u003e Designed for frequent cleaning in systems with sediment and debris, making it ideal for residential and commercial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Can be installed in any position with options for pit\/vault installations using the sealed cage option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What pressure reduction ratio is recommended for the Zurn 2-600XL?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Multiple installations are recommended for wide demand variations or where the desired pressure reduction exceeds a 4:1 ratio (e.g., 200 psi inlet reduced to 50 psi outlet).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins 2-600XL be installed vertically or horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Zurn 2-600XL may be installed in any position. For pit, vault, or inside applications, specify the \"SC\" sealed cage option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I adjust the pressure on this valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use a downstream pressure gauge to verify the correct pressure setting. Do not bottom the adjustment bolt on the bell housing. The standard model is factory preset at 50 psi with a reduced pressure range of 25-75 psi.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42884240769087,"sku":"2-600XL","price":1552.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/2-600XL_AF.jpg?v=1771003138","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-2-600xl-water-pressure-reducing-valve-with-by-pass-strainer","provider":"BottleFillingStations.com","version":"1.0","type":"link"}