{"product_id":"wilkins-12-375xlft-12-reduced-pressure-backflow-preventer","title":"Wilkins 12-375XLFT | 1\/2\" Reduced Pressure Backflow Preventer","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 12-375XLFT is a reduced pressure principle backflow preventer assembly designed to protect potable water systems against backsiphonage and backpressure contamination where health hazards exist.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 175 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e FNPT Threads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-375XLFT:\u003c\/strong\u003e 3\/4 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-375XLFT:\u003c\/strong\u003e 1 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-375XLFT:\u003c\/strong\u003e 1 1\/2 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-375XLFT:\u003c\/strong\u003e 2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHousing: Reinforced Nylon (FDA approved)\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall Valves: Low Lead Cast Bronze, ASTM B 584\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eInternals: Delrin\u003c\/li\u003e\n\u003cli\u003eInternals: Nylon\u003c\/li\u003e\n\u003cli\u003eStruts: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The Zurn 12-375XLFT assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. If installed indoors, the installation shall be supplied with an air gap adapter.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA compliant C511; USC Foundation Approved; NSF\/ANSI\/CAN 61 \u0026amp; 372\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 372 with less than 0.25% weighted average lead content, ideal for potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Protection:\u003c\/strong\u003e Protects against both backsiphonage and backpressure of contaminated water into potable water supply systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e FDA-approved reinforced nylon housing with stainless steel components ensures long-lasting performance and corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Test Fitting:\u003c\/strong\u003e Features integral male 45° flare SAE test fitting for convenient testing and maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the required installation height for the Zurn 12-375XLFT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be installed at a minimum of 12 inches and a maximum of 30 inches above adequate floor drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this backflow preventer be submerged or installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the unit must not be submerged. For indoor installations, an air gap adapter is required. For outdoor applications, a protective enclosure is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum working pressure and temperature for the 12-375XLFT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The maximum working water pressure is 175 psi, maximum working water temperature is 180°F, and hydrostatic test pressure is 350 psi.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914889531455,"sku":"12-375XLFT","price":910.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/2-375XL_AF_fcc9e4f0-b302-4baa-8185-6624e531fc44.png?v=1770568152","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-12-375xlft-12-reduced-pressure-backflow-preventer","provider":"BottleFillingStations.com","version":"1.0","type":"link"}