{"product_id":"wilkins-114-975xl2seu-rp-backflow-preventer-1-14-union-ball-valves","title":"Wilkins 114-975XL2SEU | RP Backflow Preventer, 1 1\/4\", Union Ball Valves","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 114-975XL2SEU is a reduced pressure principle backflow prevention assembly designed to protect potable water from contamination, ideal where a health hazard exists.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-975XL2SEU:\u003c\/strong\u003e 1\/2 Inches size version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2SEU:\u003c\/strong\u003e 1 Inches size version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-975XL2SEU:\u003c\/strong\u003e 2 Inches size version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-975XL2SEU:\u003c\/strong\u003e 3\/4 Inches size version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone and Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall valve handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, the installation shall be supplied with an air gap adapter.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF\/ANSI\/CAN 61 \u0026amp; 372; UL Classified; C-UL Classified\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides protection against both backsiphonage and backpressure of contaminated water where a potential health hazard exists.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 61 and 372 standards with less than 0.25% weighted average lead content for safe potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnion Ball Valve Design:\u003c\/strong\u003e Full port union ball valves provide convenient shut-off and easy removal for maintenance and testing without cutting piping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum and maximum installation height for the Zurn 114-975XL2SEU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is an air gap fitting required for the Zurn 114-975XL2SEU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, if the assembly is installed indoors, an air gap adapter (Model AG) is required to ensure proper drainage and prevent submersion of the unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the street elbows (SE option) included with this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The SE suffix indicates the unit comes with street elbows for 3\/4 inch and 1 inch sizes, providing convenient connection options for specific installation configurations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914884714559,"sku":"114-975XL2SEU","price":2395.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/1-975XL2SE_AF_aa09b82c-ff66-40b0-a9b1-6e8aa50d5156.png?v=1770568097","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-114-975xl2seu-rp-backflow-preventer-1-14-union-ball-valves","provider":"BottleFillingStations.com","version":"1.0","type":"link"}