{"product_id":"wilkins-114-950xlt2-double-check-backflow-preventer-lead-free","title":"Wilkins 114-950XLT2 | Double Check Backflow Preventer, Lead-Free","description":"\u003cp\u003eThe Wilkins 114-950XLT2 is a lead-free double check valve assembly designed to protect potable water systems from backsiphonage and backpressure in non-health hazard applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1015, NSF\/ANSI\/CAN 61 \u0026amp; 372\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/wilkins-112-950xlt2-top-access-double-check-valve-assembly\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e112-950XLT2:\u003c\/strong\u003e\u003c\/a\u003e 1 1\/2 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/wilkins-1-950xlt2-double-check-valve-assembly\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e1-950XLT2:\u003c\/strong\u003e\u003c\/a\u003e 1 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/wilkins-2-950xlt2-double-check-backflow-preventer\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e2-950XLT2:\u003c\/strong\u003e\u003c\/a\u003e 2 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-34-950xlt2-double-check-valve-assembly\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e34-950XLT2:\u003c\/strong\u003e\u003c\/a\u003e 3\/4 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow Lead Cast Bronze ASTM B 584 (main valve body and access covers)\u003c\/li\u003e\n\u003cli\u003eStainless Steel, 300 Series (fasteners, springs, and ball valve handles)\u003c\/li\u003e\n\u003cli\u003eSilicone (elastomers)\u003c\/li\u003e\n\u003cli\u003eBuna Nitrile (elastomers)\u003c\/li\u003e\n\u003cli\u003eNoryl™ (polymers)\u003c\/li\u003e\n\u003cli\u003ePlastic (test cock cover)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. If installed below grade, be certain adequate drainage is provided to prevent the device from being submerged.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1015; cUPC Listed; CSA Certified B64.5; AWWA Compliant C510; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal installations only); NSF\/ANSI\/CAN 61 and 372\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 372 with less than 0.25% weighted average lead content for safe potable water use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Access Design:\u003c\/strong\u003e Allows easy maintenance and testing without removing the valve from the line, reducing downtime and labor costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtected Test Cocks:\u003c\/strong\u003e Test cock plugs prevent fouling from insects, dirt, and debris, ensuring reliable performance and accurate testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Ball Valves:\u003c\/strong\u003e Threaded ANSI B1.20.1 end connections with full port ball valves provide maximum flow capacity and ease of installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What size is the Zurn 114-950XLT2 and what are the pressure and temperature ratings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn 114-950XLT2 is a 1 1\/4 inch model rated for 175 PSI maximum working water pressure and 180°F maximum working water temperature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this backflow preventer be installed vertically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit can be installed in both horizontal and vertical flow-up configurations per ASSE 1015 and other standards compliance, though USC Foundation approval applies to horizontal installations only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What maintenance access does this valve provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Wilkins 114-950XLT2 features top access design with separate access covers for each check valve at a 45° angle, allowing service and maintenance without removing the assembly from the line.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914883305535,"sku":"114-950XLT2","price":1294.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/114-950XLT2_AF.jpg?v=1771002984","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-114-950xlt2-double-check-backflow-preventer-lead-free","provider":"BottleFillingStations.com","version":"1.0","type":"link"}