{"product_id":"wilkins-114-500xl3-1-14-inch-pressure-reducing-valve","title":"Wilkins 114-500XL3 | 1 1\/4 Inch Pressure Reducing Valve","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 114-500XL3 is a 1 1\/4 inch pressure reducing valve designed for commercial plumbing and industrial water systems, featuring balanced piston design with integral venturi for superior flow performance and thermal expansion protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 400 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, cUPC, CSA B356\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreaded Connections:\u003c\/strong\u003e FNPT per ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-500XL3:\u003c\/strong\u003e 1 1\/2 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-500XL3:\u003c\/strong\u003e 1 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e212-500XL3:\u003c\/strong\u003e 2 1\/2 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-500XL3:\u003c\/strong\u003e 2 Inch version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-500XL3:\u003c\/strong\u003e 3 Inch version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low lead cast bronze ASTM B806\u003c\/li\u003e\n\u003cli\u003eBell housing: Low lead cast bronze ASTM B806\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless steel, 300 series\u003c\/li\u003e\n\u003cli\u003eStem: Stainless steel, 300 series\u003c\/li\u003e\n\u003cli\u003ePlunger: Stainless steel, 300 series\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA approved), EPDM (FDA approved)\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless steel, 300 series\u003c\/li\u003e\n\u003cli\u003eCartridge: Noryl™\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eThe Zurn 114-500XL3 may be installed in any position on potable water lines. Multiple installations in series are required when the desired pressure reduction is more than 3 to 1. The assembly shall be installed with sufficient side clearance for testing and maintenance in accordance with manufacturer's instructions and local plumbing codes.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1003; cUPC Listed; CSA Certified B356; NSF\/ANSI\/CAN 61; NSF\/ANSI\/CAN 372\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Provides smooth and responsive performance under varying flow demands while protecting against inlet pressure changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Venturi Technology:\u003c\/strong\u003e Patented design delivers best-in-class flow performance for commercial and industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Expansion Protection:\u003c\/strong\u003e Direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance:\u003c\/strong\u003e Removable cartridge and corrosion resistant materials allow for accessible maintenance without removing the body from the line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the adjustable outlet pressure range for the Zurn 114-500XL3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The adjustable outlet pressure range is 15 to 75 PSI, with a factory preset of 50 PSI. A pressure gauge must be used downstream when adjusting to verify correct pressure setting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this valve be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Model 500XL3 may be installed in any position, including horizontal, vertical, or at an angle, providing flexibility for various installation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: When are multiple valves required in series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Multiple installations in series are required when the desired pressure reduction is more than 3 to 1 ratio (i.e., 150 PSI inlet reduced to 50 PSI outlet) to ensure proper valve performance and longevity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42884238835775,"sku":"114-500XL3","price":1168.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/2-500XL3_F_8199e056-4982-423b-9734-e33215a0987b.png?v=1770312597","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-114-500xl3-1-14-inch-pressure-reducing-valve","provider":"BottleFillingStations.com","version":"1.0","type":"link"}