{"product_id":"wilkins-112-975xl2s-34-rp-backflow-preventer-with-strainer","title":"Wilkins 112-975XL2S | 3\/4\" RP Backflow Preventer with Strainer","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 112-975XL2S is a 3\/4\" reduced pressure principle backflow preventer with integrated bronze Y-type strainer, designed to protect potable water systems against backsiphonage and backpressure where health hazards exist.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded FNPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-975XL2S:\u003c\/strong\u003e 1 1\/4 Inches version with strainer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2S:\u003c\/strong\u003e 1 Inch model with strainer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-975XL2S:\u003c\/strong\u003e 2 Inches model with strainer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-975XL2S:\u003c\/strong\u003e 3\/4 Inches version with strainer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow-lead cast bronze body (ASTM B584)\u003c\/li\u003e\n\u003cli\u003eLow-lead cast bronze access covers (ASTM B584)\u003c\/li\u003e\n\u003cli\u003eStainless steel fasteners, 300 series\u003c\/li\u003e\n\u003cli\u003eSilicone elastomers\u003c\/li\u003e\n\u003cli\u003eBuna Nitrile elastomers\u003c\/li\u003e\n\u003cli\u003eNoryl™ polymers\u003c\/li\u003e\n\u003cli\u003eStainless steel springs, 300 series\u003c\/li\u003e\n\u003cli\u003eStainless steel ball valve handles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eThe Zurn 112-975XL2S shall be installed on potable water lines in accordance with local codes and manufacturer's instructions per the latest edition of the Uniform Plumbing Code. Assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance, ensuring no part of the unit can be submerged. Indoor installations require an air gap adapter.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; NSF\/ANSI\/CAN 61 \u0026amp; 372 certified; UL Classified; C-UL Classified; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Certified to NSF\/ANSI\/CAN 61 \u0026amp; 372 with less than 0.25% weighted average lead content for safe potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Protection:\u003c\/strong\u003e Guards against both backsiphonage and backpressure of contaminated water where potential health hazards exist.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Strainer Protection:\u003c\/strong\u003e Bronze Y-type strainer provides debris protection to extend valve life and maintain optimal performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or entire device from the line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum working pressure and temperature for the Zurn 112-975XL2S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit is rated for a maximum working water pressure of 175 PSI and maximum working water temperature of 180°F, with a hydrostatic test pressure of 350 PSI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where should the Wilkins 112-975XL2S be installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Install the assembly 12 to 30 inches above adequate drainage with sufficient clearance for testing and maintenance. Indoor installations require an air gap adapter, and no part of the unit should be submerged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What certifications does this backflow preventer have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly is ASSE Listed 1013, cUPC Listed, CSA Certified B64.4, AWWA Compliant C511, NSF\/ANSI\/CAN 61 \u0026amp; 372 certified, and UL\/C-UL Classified for comprehensive compliance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914874556479,"sku":"112-975XL2S","price":2260.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/114_2-975XL2_AL_ba5b50b8-9e2b-42f8-a32c-1554bc8fb63b.png?v=1770567994","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-112-975xl2s-34-rp-backflow-preventer-with-strainer","provider":"BottleFillingStations.com","version":"1.0","type":"link"}