{"product_id":"wilkins-112-500xlhlr-1-12-water-pressure-reducing-valve-with-bypass-check","title":"Wilkins 112-500XLHLR | 1 1\/2\" Water Pressure Reducing Valve with Bypass Check","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 112-500XLHLR is a water pressure reducing valve with integral by-pass check valve designed for commercial and industrial applications, providing reliable pressure control and thermal expansion protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, cUPC, CSA B356\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Single Union FNPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-500XLHLR:\u003c\/strong\u003e 1 1\/4 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-500XLHLR:\u003c\/strong\u003e 1 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-500XLHLR:\u003c\/strong\u003e 2 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-500XLHLR:\u003c\/strong\u003e 3\/4 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-500XLHLR:\u003c\/strong\u003e 3 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eStem \u0026amp; Plunger: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA approved) \/ EPDM (FDA approved)\u003c\/li\u003e\n\u003cli\u003eCap Gaskets: Natural Vulcanized Fibre \/ Acetal (Delrin™ 500)\u003c\/li\u003e\n\u003cli\u003eSprings: Oil Tempered Wire, ASTM A 229\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. The assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500XL may be installed in any position. If installed in a pit, vault, or inside application, specify the \"SC\" sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 3 to 1 (i.e.: 150 psi inlet reduced to 50 psi outlet).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1003; cUPC Listed; CSA Certified B356; City of Los Angeles Approved; NSF\/ANSI\/CAN 61 \u0026amp; 372\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Pressure Range:\u003c\/strong\u003e HLR option provides 10 psi to 125 psi spring range with factory setting at 50 psi for versatile applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Expansion Protection:\u003c\/strong\u003e Direct acting integral by-pass check valve prevents buildup of excessive system pressure caused by thermal expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Can be installed in any position, making it suitable for various applications including pits and vaults with SC option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Enables smooth and responsive reaction to changes in system flow demand while providing protection from inlet pressure changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the HLR option on the Zurn 112-500XLHLR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The HLR option provides a 10 psi to 125 psi spring range, factory set at 50 psi, offering extended pressure adjustment capability for diverse applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins 112-500XLHLR be installed vertically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Model 500XL can be installed in any position, including vertical, horizontal, or angled installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Do I need a pressure gauge for adjustment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom the adjustment bolt on bell housing.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914871377983,"sku":"112-500XLHLR","price":2483.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/1-500XL-01-01_0104ec32-23e5-4a5a-a0c4-a05a4db3b705.png?v=1770567958","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-112-500xlhlr-1-12-water-pressure-reducing-valve-with-bypass-check","provider":"BottleFillingStations.com","version":"1.0","type":"link"}