{"product_id":"wilkins-10-zw209fpg-10-fire-protection-prv-grooved-ends","title":"Wilkins 10-ZW209FPG | 10\" Fire Protection PRV, Grooved Ends","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 10-ZW209FPG is a pilot operated pressure reducing valve designed for fire suppression systems to reduce high inlet pressures to safe, stable outlet pressure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Size:\u003c\/strong\u003e 10 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inlet Pressure Rating:\u003c\/strong\u003e 300 psi grooved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e 33°F to 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e UL and C-UL Listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Grooved (AWWA C606)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-ZW209FPG:\u003c\/strong\u003e 8 Inch valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-ZW209FPG:\u003c\/strong\u003e 6 Inch valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-ZW209FPG:\u003c\/strong\u003e 4 Inch valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-ZW209FPG:\u003c\/strong\u003e 3 Inch valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e212-ZW209FPG:\u003c\/strong\u003e 2 1\/2 Inch valve size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-ZW209FPG:\u003c\/strong\u003e 2 Inch valve size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Ductile Iron ASTM A536\u003c\/li\u003e\n\u003cli\u003eMain Valve Cover: Ductile Iron ASTM A536\u003c\/li\u003e\n\u003cli\u003eDisc Guide: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eDisc: Buna-N Rubber\u003c\/li\u003e\n\u003cli\u003eDiaphragm: Nylon Reinforced Buna-N\u003c\/li\u003e\n\u003cli\u003eStem: Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSpring: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eThe upstream and downstream pressure gauges are required by Underwriters Laboratories (UL). A relief valve of not less than 1\/2 inch in size MUST be installed on the downstream side of the pressure control valve. Adequate drainage for the relief valve discharge must be provided. The valve is to be installed in accordance with NFPA 13 or NFPA 14 standards and maintained per NFPA 25.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eANSI\/AWWA C530; AWWA C606; UL and C-UL Listed; NFPA 13; NFPA 14; NFPA 25\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot Operated Control:\u003c\/strong\u003e Maintains constant downstream pressure regardless of flow rate or varying inlet pressures through modulating pilot assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e Red epoxy coating on all internal and external surfaces provides FDA approved corrosion resistance for long-term durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Ready:\u003c\/strong\u003e Includes wye strainer, inlet and outlet UL\/FM pressure gauges with 3-way isolation valves for quick installation and easy adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Adjustment Range:\u003c\/strong\u003e Field adjustable pilot spring range from 50-165 psi residual pressure with 175 psi maximum static pressure capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the adjustable pressure range for the Zurn 10-ZW209FPG?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The pilot control is field adjustable from 50 psi to 165 psi residual pressure (155 psi maximum for 10 inch size) with a maximum static pressure of 175 psi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What flow rates can this valve handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn 10-ZW209FPG has a minimum flow rate of 35 GPM and a maximum flow rate of 6000 GPM. A minimum flow of 600 GPM is required to initially set the valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What installation orientation is recommended for this valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The recommended installation orientation is horizontal with the valve cover up. For 6 inch and larger valves, horizontal installation with cover up is required due to difficulty bleeding air and performing maintenance in vertical orientations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42983788150847,"sku":"10-ZW209FPG","price":22724.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/ZW209FP_AF.png?v=1772854524","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-10-zw209fpg-10-fire-protection-prv-grooved-ends","provider":"BottleFillingStations.com","version":"1.0","type":"link"}