{"product_id":"wilkins-1-950xlt2ft-1-double-check-valve-assembly-top-access","title":"Wilkins 1-950XLT2FT | 1\" Double Check Valve Assembly, Top Access","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 1-950XLT2FT is a top access double check valve assembly designed to protect potable water lines from backsiphonage and backpressure contamination where non-health hazards exist.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1015, cUPC, CSA B64.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\/4-950XLT2FT:\u003c\/strong\u003e 3\/4 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 1\/4-950XLT2FT:\u003c\/strong\u003e 1 1\/4 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 1\/2-950XLT2FT:\u003c\/strong\u003e 1 1\/2 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-950XLT2FT:\u003c\/strong\u003e 2 Inches version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless steel, 300 series\u003c\/li\u003e\n\u003cli\u003eTest cock cover: Plastic\u003c\/li\u003e\n\u003cli\u003eBall valve handles: Stainless steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. The Zurn 1-950XLT2FT assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. If installed below grade, ensure adequate drainage is provided to prevent the device from being submerged.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1015; cUPC Listed; CSA Certified B64.5; AWWA Compliant C510; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal installations only); Meets the requirements of NSF\/ANSI\/CAN 61 and 372 (Less than 0.25% Weighted Average Lead Content)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Access Design:\u003c\/strong\u003e First and second check valves located at 45° angle and accessible for maintenance from the top without removing device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Test Cocks:\u003c\/strong\u003e Equipped with \"Fast Test\" test cocks accessible from the top, protected from debris by plugs for reliable testing and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Meets NSF\/ANSI\/CAN 372 standards with less than 0.25% weighted average lead content, ideal for potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Ball Valves:\u003c\/strong\u003e Provides maximum flow capacity and reliable shutoff for service and maintenance operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the recommended installation height for the Wilkins 1-950XLT2FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the Zurn 1-950XLT2FT be installed in both horizontal and vertical positions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the assembly is certified for both horizontal and vertical flow-up installations according to ASSE 1015 and other applicable standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of backflow protection does this assembly provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The double check valve assembly protects against both backsiphonage and backpressure of polluted water where a potential non-health hazard exists.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914861875263,"sku":"1-950XLT2FT","price":534.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/950XLT2_AF_8a287655-146f-42bb-8509-729b044cd50f.png?v=1770567845","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-1-950xlt2ft-1-double-check-valve-assembly-top-access","provider":"BottleFillingStations.com","version":"1.0","type":"link"}