{"product_id":"wilkins-1-950xl3-reduced-pressure-principle-backflow-preventer-1-inches","title":"Wilkins 1-950XL3 | Reduced Pressure Principle Backflow Preventer, 1 Inches","description":"\u003cp\u003e\nThe Wilkins 1-950XL3 is a Reduced Pressure Principle Backflow Prevention Assembly designed to protect potable water lines from contamination.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 25\/175 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 180°F (82°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded FNPT ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-950XL3:\u003c\/strong\u003e 1 1\/2 Inches size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-950XL3:\u003c\/strong\u003e 1 1\/4 Inches size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-950XL3:\u003c\/strong\u003e 2 Inches size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-950XL3:\u003c\/strong\u003e 3\/4 Inches size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow Lead Bronze ASTM B584 (main valve body and access covers)\u003c\/li\u003e\n\u003cli\u003e300 Series Stainless Steel (fasteners and springs)\u003c\/li\u003e\n\u003cli\u003eSilicone (FDA Approved elastomers)\u003c\/li\u003e\n\u003cli\u003eBuna Nitrile (FDA Approved elastomers)\u003c\/li\u003e\n\u003cli\u003eNoryl™ (polymers)\u003c\/li\u003e\n\u003cli\u003eStainless Steel (ball valve handles)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1013; cUPC; CSA B64.4; UL Classified; C-UL Classified; AWWA C511; NSF\/ANSI\/CAN 61; NSF\/ANSI\/CAN 372; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Protection:\u003c\/strong\u003e NSF\/ANSI\/CAN 372 certified with less than 0.25% weighted average lead content for safe potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Protection:\u003c\/strong\u003e Provides protection against both backsiphonage and backpressure of contaminated water where a potential health hazard exists.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance Access:\u003c\/strong\u003e First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Ball Valves:\u003c\/strong\u003e Equipped with full port ball valves and integral test fittings for efficient testing and operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum working pressure required for the Zurn 1-950XL3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The minimum working water pressure required is 25 PSI.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the Zurn 1-950XL3 be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be installed 12 to 30 inches above an adequate drain with sufficient side clearance. The unit must not be submerged.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What temperature range can this backflow preventer handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit is rated for temperatures from 33°F minimum to 180°F maximum.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914861023295,"sku":"1-950XL3","price":491.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/1-950XL3_F.jpg?v=1771003029","url":"https:\/\/bottlefillingstations.com\/products\/wilkins-1-950xl3-reduced-pressure-principle-backflow-preventer-1-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}