{"product_id":"hoshizaki-hs-5061-drain-pump-kit-for-undercounter-icemaker","title":"Hoshizaki HS-5061 | Drain Pump Kit for Undercounter Icemaker | Check Valve with Hoses and Clamps","description":"\u003cp\u003eThe Hoshizaki HS-5061 drain pump is a complete kit for Hoshizaki undercounter icemakers installed in spaces without a floor drain. It removes purged and melted water through a factory-installed check valve and includes all hoses, clamps, and screws for installation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; table-layout: fixed;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDrain pump kit for undercounter icemakers without direct drain access, with a factory-installed check valve and an internal safety switch that stops ice production if the pump fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with Hoshizaki undercounter models including \u003ca href=\"https:\/\/bottlefillingstations.com\/products\/hoshizaki-am-50baj-undercounter-top-hat-cuber-icemaker-air-cooled-22-lbs-capacity\" target=\"_blank\"\u003eAM-50 Series\u003c\/a\u003e, C-100 Series, C-101 Series, KM-61BAH, and KM-101BAH and related models such as certain C-80 and KM-80\/81\/115\/116BAJ series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum vertical lift approximately 8 inches and maximum horizontal run approximately 20 inches.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Hoses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\" ID × 6.5\" vinyl drain hose, 3\/8\" ID × 27.5\" vinyl vent hose, and 1\/2\" ID × 10' high-pressure clear PVC discharge hose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware \u0026amp; Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 small clamp (vent hose), 1 medium clamp (discharge hose), 2 large clamps (drain hose\/elbow connections), 2 hose clips, and 2 stainless steel truss-head screws (4×8). 1-year parts and labor warranty.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Application:\u003c\/strong\u003e Solves drainage issues for icemakers in locations without access to gravity drains, expanding installation possibilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Kit:\u003c\/strong\u003e Includes all necessary components for installation, simplifying the setup process for technicians.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Designed to meet safety standards and regulations, ensuring safe operation in commercial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e Engineered specifically for Hoshizaki icemakers, guaranteeing compatibility and efficient drainage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eWhat's Included:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 Drain Pump Assembly\u003c\/li\u003e\n\u003cli\u003e1 Vinyl Hose (drain hose) (5\/8\" ID×6.5\")\u003c\/li\u003e\n\u003cli\u003e1 Vinyl Hose (vent hose) (3\/8\" ID×27.5\")\u003c\/li\u003e\n\u003cli\u003e1 High Pressure Clear PVC Hose (discharge hose) (1\/2\" ID×10')\u003c\/li\u003e\n\u003cli\u003eVarious clamps and clips for secure hose connections\u003c\/li\u003e\n\u003cli\u003e2 Truss Head Screws (4×8, SS)\u003c\/li\u003e\n\u003cli\u003eInstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the Hoshizaki HS-5061 Drain Pump Require Professional Installation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. Hoshizaki states that only qualified service technicians should install and service the HS-5061 drain pump. A plumbing permit and a licensed plumber may be required in some areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How Far and How High Can the HS-5061 Pump Drain Water?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The HS-5061 ice machine drain pump supports a Maximum vertical lift approximately 8 inches and maximum horizontal run approximately 20 inches. Keep the discharge hose free of traps and kinks to maintain proper flow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How Is the HS-5061 Drain Pump Powered?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The HS-5061 plugs directly into the icemaker's drain pump connector after the factory jumper plug is removed, so no separate outlet is needed for the pump. The icemaker itself must be plugged into a properly grounded, independent 3-prong wall outlet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What Happens If the HS-5061 Drain Pump Backs Up or Fails?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e An internal safety switch shuts off the icemaker if the drain pump fills to capacity, while the pump keeps running. The icemaker restarts automatically once the water level drops, which helps prevent overflows and water damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the HS-5061 Discharge Hose Connect Directly to a Floor Drain?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Hoshizaki requires a minimum 2\" air gap between the end of the discharge hose and the floor drain or drain piping. The pump has a factory-installed check valve, so do not install any additional check valves.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What Warranty Comes with the Hoshizaki HS-5061 Drain Pump?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The HS-5061 carries a 1-year parts and labor warranty that begins on the drain pump's installation date. Be sure to register your icemaker for warranty validation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where Does the HS-5061 Drain Pump Mount on the Icemaker?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The HS-5061 sits in the open space at the rear of the icemaker and overhangs the base slightly. It must be level, and the icemaker's copper tubing should be moved carefully if needed so it doesn't touch the pump or hoses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How Do You Test the HS-5061 Drain Pump After Installation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Slowly pour 24 to 30 oz of water over the storage bin drain hole and confirm it discharges through the hose, then check that the pump shuts off and there are no leaks. At least 24 oz of water is needed to activate the pump.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why Is the Vent Hose Important on the HS-5061?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The drain pump will not operate correctly with a blocked or kinked vent hose. On these undercounter models, the supplied 3\/8\" ID × 27.5\" vent hose must be cut to 19.5\" and secured to the icemaker with the included hose clips and screws. A blocked or kinked vent hose will prevent correct pump operation and can cause water damage.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003e\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eContact us now\u003c\/a\u003e\u003c\/i\u003e\u003c\/p\u003e","brand":"Hoshizaki","offers":[{"title":"Default Title","offer_id":40485556584511,"sku":"HS-5061","price":525.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/973982.jpg?v=1709551313","url":"https:\/\/bottlefillingstations.com\/products\/hoshizaki-hs-5061-drain-pump-kit-for-undercounter-icemaker","provider":"BottleFillingStations.com","version":"1.0","type":"link"}